Filter Results By:
Products
Applications
Manufacturers
Millimetre Band
extremely High Frequency in the range of 30 to 300 gigahertz.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (m)
85562A
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight
-
product
VDI Erickson PM5B MM–Wave Power Meter with W-Band Sensor, Optional Tapers to 1.5 THz
N1913PM5B
N1913PM5B is a Virginia Diodes, Inc./Erickson PM5B calorimetric mm-wave power meter, with a W-Band sensor for power measurement over a frequency range of 75-110 GHz.
-
product
Oscilloscope 40 GHz, 4 Channels, 1.85 mm Inputs
UXR0404B
XR0404B Infiniium UXR-Series is the 40 GHz, 4 channel, 1.85 mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
Footspacing Kit
10759A
The Keysight 10759A Foots pacing Kit, included in the Keysight 55282A Flatness Accessory Kit, provides three precision baseplates with 50.8 mm (2 in), 101.6 mm (4 in) and 152.4 mm (6 in) pad spacing. As an accessory to the Keysight 5530Laser Calibration System, the kit simplifies the mounting of the flatness mirror used in flatness measurement applications. The Keysight 10759A minimizes the grid setup and data accumulation time required for plate calibration.
-
product
Cable Assembly, 3.5 mm (m) to 3.5 mm (m), DC to 26.5 GHz
11500E
The Keysight 11500E is a 61 cm (24 in) 3.5-mm male to 3.5 mm male cable assembly with a frequency range of dc to 26.5 GHz.
-
product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
product
Oscilloscope 40 GHz, 4 Channels, 1 mm Inputs
UXR0404BP
UXR0404BP Infiniium UXR-Series is the 40 GHz, 4 channel, 1mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
2-26.5 GHz Traveling Wave Amplifier
1GG7-8045
The 1GG7-8045 is a broadband GaAs MMIC Traveling Wave Amplifier designed for high output power and moderate gain over the full 2 to 26.5 GHz frequency range. Seven MESFET cascode stages provide a flat gain response, making the 1GG7-8045 an ideal wideband power block. Ebeam lithography is used to produce gate lengths of ~0.3 mm. The 1GG7-8045 incorporates advanced MBE technology, TiPtAu gate metallization, silicon nitride passivation, and polyimide for scratch protection.
-
product
Beam Bender
10707A
The Keysight 10707A bends the incoming beam at a 90-degree angle and is designed for beam diameters of 6 mm or less . Includes a housing for standard mounting.
-
product
Flexible Cable Set, 2.4 Mm To 7 Mm
85135F
Achieve phase stability with these 62.9-cm cables when a DUT is connected between cable ends
-
product
Oscilloscope 59 GHz, 2 Channels, 1 mm Inputs
UXR0592BP
The UXR0592BP is the 59 GHz, 2 channel, 1mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
product
One Axis Differential Interferometer
10719A
The Keysight 10719A One Axis Differential Interferometer makes either a differential linear or angular measurement for use in single and multiple axis applications. The linear measurement gauges the displacement between two objects, such as a stage and an optical column or inspection tool. The 10719A also measures either pitch or roll. An angle is measured when both reference and measurement beams measure to the same mirror. The 10721A provides high immunity to unwanted interferometer displacement, such as thermal expansion. It is a modular, compact design with monolithic optics for maximized mechanical stability. Use of a small 3 mm beam helps decrease Abb offset error.
-
product
4% Beam Splitter
10725B
The 10725B 4% beam splitter, designed for beam diameters of 9 mm or less, reflects 4% of the total incoming laser beam and transmits 96% straight through. This optic is without housing and requires a user-supplied mount.
-
product
Beam Bender
10726A
The Keysight 10726A bends the incoming beam at a 90-degree angle and is designed for beam diameters of 9 mm or less. This bare optic requires a user-supplied mount.
-
product
Plane Mirror
10728A
The Keysight 10728A is a normal incidence plane mirror for beam diameters of 9 mm or less. It is a bare optic that requires a user-supplied mount. It is typically used with the 10735A and 10736A three axis interferometers.
-
product
Oscilloscope 70 GHz, 2 Channels, 1 mm Inputs
UXR0702BP
The UXR0702BP is the 70 GHz, two-channel, 1 mm input Infiniium UXR-Series real-time oscilloscope.
-
product
+40dBm Optical Power Head
81628B
The 81628B is used with the threaded type adapters. When the adapter is removed, the 8 mm diameter aperture is available for input to open beams or customized fiber holders. The heads are connected to the 816x mainframes using the 81618A single channel or 81619A dual-channel interface module.
-
product
Semi-Rigid Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131C
The Keysight 85131C is an 81 cm (32 in) long1 semi-rigid cable with a 3.5 mm female2-to-PSC-3.5 mm female connector. Cable frequency range is DC to 26.5 GHz with a return loss of 17 dB or better. Insertion loss is 0.43 * sqrt(f) + 0.3, where f is frequency in gigahertz, for the test port connector and 2.5 dB at maximum frequency for the device connector. Phase stability of the semi-rigid / flexible cables is specified with a 90-degree bend using a 4 to 3-inch radius. Stability1 of the 85131C is less than 0.06 dB, and phase is 0.16 * f + 0.5, where f is frequency in gigahertz.
-
product
Beam Bender BK7, Fixed Vertical-Bend Mount
E1834Z
The E1834Z is a beam bender that bends the incoming beam at a 90-degree angle and is designed for beam diameters of 9 mm or less. This referenced optics uses high performance vertical mount to deliver laser beam throughout a measurement system. The 8 flexure feet are designed for stable beam pointing.
-
product
Two Axis Differential Interferometer
10721A
The Keysight 10721A Two Axis Differential Interferometer, when used in multiple axis applications, simultaneously makes two differential measurements linear and angular (yaw) displacement. Both measurements reference external mirror mounted to an object such as a column or inspection tool. The 10721A provides high immunity to unwanted interferometer displacement, such as thermal expansion. It is a modular, compact design with monolithic optics for maximized mechanical stability. Use of a small 3 mm beam helps decrease Abb offset error. The 10721A is similar to the 10719A Single Axis Differential Interferometer, except that it provides an additional measurement axis.
-
product
NI-9970, 2-Position, Spring Terminal Connector Plug, 3.5 mm Pitch (Qty 4)
787005-01
2-Position, Spring Terminal Connector Plug, 3.5 mm Pitch (Qty 4)
-
product
Test Port Cable, 1 Mm
11500K
Connect test ports to devices, fixtures, or probe tips with this 20-cm cable featuring a return loss of 16 dB minimum
-
product
Test Port Adapter Set, 3.5 Mm (Test Port) To Type-N
85130C
The Keysight 85130C test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 3.5 mm to type-N male adapter and a 3.5 mm to type-N female adapter. The frequency range for these adapters is dc to 18 GHz with a return loss of 28 dB or better.
-
product
In-Line Coaxial-to-Waveguide Adapter, 1.0 Mm (f) To WR-12, 60 To 90 GHz
E281CS
E281CS E281CS In-line 1.0 mm (f) - to- WR-12 waveguide adapter offers a simple way of measuring waveguide devices in E-band, 60 GHz to 90 GHz.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
110 GHz, 1.0 Mm (m-f) Test Port Cable 10 Cm
11500JK10
Connect test ports to devices, fixtures, or probe tips with this 10-cm cable
-
product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
SMD Array Type LCR Test Fixture
16034H
The 16034H is designed for impedance evaluations of array-type SMD.The minimum SMD size that this fixture is adapted to evaluate is 1.6(L)x0.8(W)[mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact each of the elements of the array-type component.